First, please find the white singal wire, see picture
There are three wires inside_red, black and yellow
For the temperature probe, please open the top box, there are three wires_red, red and green inside.
The connection is as follows.
White single wire Thermocouple wire
Red———————————Red
Black——————————-Red
Yellow——————————-Green
Please connect as above and check the temperature display. If the temperature display is “HHHH”, change the position of the green wire with the first red wire.
For the solenoid, you can see two black wires: connect these two wires to the red and black wires on the single white wire.
There is no particular order of connection, but please make the red on the same side.
The one connected to the ground wire does not need to be connected.